Thermography Blower Doors Services Gallery Contacts

Services

Thermal imaging inspection of building and structures is an effective method of enclosing structuresdiagnostic upon construction works completion and during operational cycle, namely:

1. Determination of partial and general heat leakage.

2. Finding out the concealed construction defects.

  • Places of air and water leakage (imperfect joint packing from outside, mastic compound film peeling from a concrete surface, insufficient thermit crimping and cracks in matrix and mastic, defects of window units and openings : poor walls calking by a putty, through cracks in connections of the bottom box elements, mastic discretion in the catch mouth of window block joint);
  • Deterioration of resistance to the heat transfer (absence of heat-insulation, abnormal moisture, poor brick work, improper architectural and building solutions etc.);
  • Defective panels of enclosing structures(violations of the insulant’s thickness and placing, moisture adsorption in the insulant, unit mass overstating of LECA, insulant subsidence, spall of the edge of panel).

3. Specification (evaluation) of enclosing structures resistance to the heat transfer.

 

  Тепловизионное обследование квартиры.

 110 EUR (цена с налогом)

  Тепловизионное обследование частного дома  1 этаж.

 170 EUR (цена с налогом)

  Тепловизионное обследование частного дома  2 и более  этажей.

 220 EUR (цена с налогом)

  •  выезд за город 0,23 Ls 1 км (дорога до объекта счетается в два конца).

 

Infra-red image of the "Warm Floor" system.  Leaking location.

Thermal imager is an easy-to-use instrument for finding and checking the location of pipes and leaking location. Even when water pipes are encased in the floor or under a plaster. The heat of pipes emanates through a surface and they can be easily located with the help of thermal imager.

The typical example of thermal imager usage is the localization of leaking in the pipes of the heater systems "Warm Floor".

Leaks in the systems of the heating plant can also be quickly located and registered with the help of thermal imager.

Determining the exact location of the leak will allow to avoid the unnecessary digging and will cut expenses.

 

Detection of structural faults.

Thermal imager is the best and fastest device forstructural faults detection. By using thermal imager it is possible to prove easily that construction works were incorrect or poorly executed. Thermal imager shows heat leakage and air losses (points of draughts) that take place in building, in a form of high-quality colorful thermal pictures. By using thermal imager it is possible to prove easily that construction works were incorrect or poorly executed. Thermal imager shows heat leakage and air losses (points of draughts) that take place in building, in a form of high-quality colorful thermal pictures. Single piece glass among double. Flaw is not visible by the naked eye.

 

Drying-out of building.

The complete drying-out of walls and other surfaces is frequently required in construction works. With the help of thermal imager it is possible to define areas where humidity is still present. They appear on an infra-red image as a "cold spot".

 

IR image shows badly isolated places in a house.

Visualization of energy losses is an improvement of heat-insulation.

Heat bridges not only specify the areas in building, where the energy is spent for nothing. These spots can also lead to condensation or deposition of moisture from the surrounding air. Mould later grows in these places, thus creating a risk for the health of the house inhabitants. Thermal imager easily determines the locations of the defects.

 

Planning of repair and quality control.

Thermal imager is very useful during reconstruction planning and for a quality evaluation upon new building inspection. During the process of building dehumidification, thermal imager allows to define the grade of drying-out and optimize this process. If this process can be quickened and if it can be well-proven with the help of infra-red image, that the building is fully dry – this building can be handed to the client quicker. It often means a bonus for the building contractor.

 

Reconstruction.

Thermal imager also gives valuable information during buildings and monuments reconstruction. Buildings covered by a mineral plaster become clearly visible in an infra-red image. By seeing load carrying structures it is possible to make a decision about expedience of their reconstruction. Separation of plaster from walls can also be recognized and prevented on the early stage that will allow minimizing the expenses.

 

Finding out the losses of air.

Thermal imager is also used for finding out the air losses through determination of air exchange level of ventilation. During this process decreased pressure is frequently created. Because air pressure outside of the building is higher than the pressure inside of the building, air will try to enter through untightened areas. Airflow can be easily visualized by thermal imager.

After such areas are identified, they can be removed, right before sheathings and details will make it expensive and it will become hard to remove this potential building defect.

 

Flat roofs leakages finding.

The roof coating leakages evaluation is also possible with the help of thermal imager. Water keeps a high temperature longer than the rest of the roof coating material and can be easily discovered by thermal imager at night, after the rest of the roof has cooled down. Instead of all roof replacement only moist areas of the roof can be recovered or replaced.

 

Heating, ventilation and air conditioning.

An internal climate in the apartment exerts an enormous influence on our well-being and working ability. The level of morbidity in companies can rise because of a bad and unhealthy climate in the building. Thermal imager can give useful information about functioning of the conditioning systems and air ventilation, and also about the radiators functioning. The location of workplaces (for example, in relation to draughts) can be optimized with the help of information received from thermal imager.

Fire safety. Existent cracks, locations of leakage and damaged brick in flues and exhaust channels of the heater systems can be easily revealed using thermal imager. Overheated areas, which are created in a flue, are easily visible by thermal imager. Flammable areas that are located too close to a heater and exhaust parts of the system also can be easily discovered.

 

Prevention of mould appearance.

Not only a building construction suffers from the mould, but also a health and allergy development hazard occurs in dwelling zones and offices. Fungus spores propagate preferably in moist areas. Mineral substances of walls, wallpapers and paint provide an excellent soil for fungi grow. Thermal imagers with special functions of the software for dew-point visualization specify the imperiled areas and automatically mark an image with a color. Thus a potential danger is revealed in time.

 

We will not only give you a visual report about a facility, but also will analyze detected problems and will offer practical methods of their solution.